Mocomtech CIM-550 User Manual
Page 277
CiM-550 IP Enabled Satellite Modem
Rev. 2
SNMP interface
CD/CIM550.IOM
251
OID Description
cim550EdmacAddress
The EDMAC slave address will set the range of
addresses of distant-end units (modems and
transceivers) which this unit will forward messages for.
Only values that are integer multiples of ten are
permitted. Setting the EDMAC slave address to 0
disables this function. Valid slave addresses are
between 0 and 9999.
cim550UnitTestMode
Unit test mode. Can be set to:
0 Normal
1
IF Loop Back
2 Digital
Loop
Back
3
IO Loop Back
4 Tx
CW
5
Tx Alternating Pattern
cim550RecenterBuffer
Command to force the modem to re-center the receive
buffer. A value of 1 (yes) is used to issue the operation.
cim550ForceRedundentSwitch
Command to force the modem into STANDBY mode if it
is in a redundant pair. A value of 1 (yes) is used to issue
the operation.
cim550UnitAlarmMask
Alarm mask conditions, in the form “abcde”, where: a =
mask Tx AIS alarm, b = mask Rx AGC alarm c = mask
buffer alarms, d = mask Rx AIS alarm e = mask Eb/No
alarm Setting any of these bytes to 0 unmasks alarm,
setting to 1 masks them. Valid values are between 0 and
11111.
cim550UnitConfigStore
Forces the unit to store the current modem configuration
in a configuration memory location defined by values 0
to 9.
cim550UnitConfigLoad
Forces the unit to retrieve the configuration memory
location defined by values 0 to 9 and to re-program the
unit with that stored configuration.
cim550OduCommEnable
Enables or disables communication, via an FSK serial
link, with a Comtech Transceiver (Outdoor unit). Can be
set to:
0 Disable
1 Enable