beautypg.com

Mocomtech CIM-550 User Manual

Page 277

background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

SNMP interface

CD/CIM550.IOM

251

OID Description

cim550EdmacAddress

The EDMAC slave address will set the range of
addresses of distant-end units (modems and
transceivers) which this unit will forward messages for.
Only values that are integer multiples of ten are
permitted. Setting the EDMAC slave address to 0
disables this function. Valid slave addresses are
between 0 and 9999.

cim550UnitTestMode

Unit test mode. Can be set to:

0 Normal

1

IF Loop Back

2 Digital

Loop

Back

3

IO Loop Back

4 Tx

CW

5

Tx Alternating Pattern

cim550RecenterBuffer

Command to force the modem to re-center the receive
buffer. A value of 1 (yes) is used to issue the operation.

cim550ForceRedundentSwitch

Command to force the modem into STANDBY mode if it
is in a redundant pair. A value of 1 (yes) is used to issue
the operation.

cim550UnitAlarmMask

Alarm mask conditions, in the form “abcde”, where: a =
mask Tx AIS alarm, b = mask Rx AGC alarm c = mask
buffer alarms, d = mask Rx AIS alarm e = mask Eb/No
alarm Setting any of these bytes to 0 unmasks alarm,
setting to 1 masks them. Valid values are between 0 and
11111.

cim550UnitConfigStore

Forces the unit to store the current modem configuration
in a configuration memory location defined by values 0
to 9.

cim550UnitConfigLoad

Forces the unit to retrieve the configuration memory
location defined by values 0 to 9 and to re-program the
unit with that stored configuration.

cim550OduCommEnable

Enables or disables communication, via an FSK serial
link, with a Comtech Transceiver (Outdoor unit). Can be
set to:

0 Disable

1 Enable