Mocomtech CIM-550 User Manual
Page 57
CiM-550 IP Enabled Satellite Modem
Rev. 2
Front Panel Menus
CD/CIM550.IOM
31
SELECT\CONFIG\TX\PWR
DISPLAY SELECTIONS/DESCRIPTION
OUTPUT POWER LEVEL MODE:
MANUAL AUPC (ENTER)
MANUAL
AUPC
EDIT OUTPUT POWER LEVEL:
-20.0 dBm (PRESS ENTER)
MANUAL display screen
Default value is 3.0 dB, and upper
limit is 9.9 dB
WARNING! AUTO UPLINK PWR
CONTRL NEEDS FRAMED MODE
AUPC warning screen is shown if
‘Framed Mode’ is not selected.
See SELECT-CONFIG-FRAME
menu.
TARGET Eb/No MAX RANGE
ALARM DEMOD-UNLOCK(ENT)
AUPC screen if ‘Framed’ mode is
selected.
ALARM
DEMOD
UNLOCK
EDIT TARGET MIN Eb/No OF
REMOTE MODEM:9.9dB (ENT
TARGET Eb/No screen
EDIT TARGET Eb/No of
the remote modem.
Default value is 3.0 dB,
and upper limit is 9.9 dB.
EDIT MAX PERMITTED POWER
INCREASE: 1dB (ENTER)
MAX RANGE screen
Default value is 1dB, and
upper limit is 9 Db
SELECT ACTION AT MAXIMUM
TX POWER: NONE TX ALARM
ALARM screen
NONE
TX