CiM-550 IP Enabled Satellite Modem
Rev. 2
SNMP interface
CD/CIM550.IOM
250
OID Description
cim550RxClockMode
Receive clock mode. Can be set to:
0 Disabled
1 Enabled
cim550RxBufferSize
Receive buffer size in bits. Can be set to:
1 256
bits
2 512
bits
3 1024
bits
4 2048
bits
5 4096
bits
cim550RxAcqSweepRange
Receive +/- acquisition sweep range of deomulation in KHz.
Can be set between 1 and 30.
cim550RxEbnoAlarmPoint
Receive Eb/No alarm point in dB. Can be set between 0
and 160 in 0.1 dB where (0=0.0 dB to 160=16.0 dB).
13.5.1.4 I
NTERFACE
P
ARAMETERS
Table 13-39. Interface Parameters OIDs
OID Description
cim550IfImpedance
IF interface impedance. Can be set to:
5 50
Ohm
7 75
Ohm
cim550InterfaceType
Unit interface type. Can only be set to IP.
4 IP
13.5.1.5 U
TILITY
P
ARAMETERS
Table 13-40. Utility Parameters OIDs
OID Description
cim550UnitFramingMode
Unit framing mode. Can be set to:
0 Unframed