Table 13-49. odu logs oids, 15 odu l – Mocomtech CIM-550 User Manual

Page 287

background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

SNMP interface

CD/CIM550.IOM

261

OID Description

OduUnitFaults

Used to Query the Alarm status of the CSAT. A integer
value will be returned between 0..262143 where the bits
that are set indicate the faults which have occurred:

bit 0

24 volt power supply

bit 1

20 volt power supply

bit 2

12 volt power supply

bit 3

10 volt power supply

bit 4

+5 volt power supply

bit 5

-5 volt power supply

bit 6

Tx Synthesizer Unlocked

bit 7

Tx IFLO Unlocked

bit 8

Rx Synthesizer Unlocked

bit 9

Rx IFLO Unlocked

bit 10

Reference lock detect

bit 11

LNA Current Alarm

bit 12

Fan Current Alarm

bit 13

Temperature Alarm

bit 14

HPA Thermal Shutdown Alarm

bit 15

Internal IIC Bus Alarm

bit 16

EEPROM Checksum

bit 17

NVRAM/RTC Low Battery Alarm

13.5.1.15 ODU L

OGS

Table 13-49. ODU Logs OIDs

OID Description

oduClearEventsLog

Can be set to 1 (yes) to issue command.

oduNumberUnreadEvents

CSAT returns the number of Stored Events which remain
unread. Value can be between 0 and 99.

oduRetrieveNext5Events

CSAT returns the oldest 5 Stored Events that have not yet
been read over the remote control. Reply format: Sub-
body{CR}Sub-body{CR}Sub-body{CR}Subbody{CR}Sub-
body,

where Sub-body=YYYYYYYYYY ZZ mmddyyhhmmss,

YYYYYYYYYY being the fault description.

ZZ being the alarm type: FT = Fault, OK = Clear, IF =
Information.

mmddyyhhmmss = date/time stamp.