beautypg.com

Mocomtech CIM-550 User Manual

Page 105

background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

Remote Control

CD/CIM550.IOM

79

Parameter
Type

Command
(Instruction

Code and
qualifier)

Arguments for

Command or

Response to
Query

Description of arguments
(note that all arguments are ASCII numeric

codes, that is, ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query
(Instruction

Code and
qualifier)

Response to

query
(target to
controller)

b defines the IF band, with 1 = 70MHz, 2 =
140MHz
c defines RX only, with 1 = RX/TX, 2 = RX only.
Example: EID=455011 (CiM-550, Rate 3/4 Turbo

Codec, 70 MHz band, RX/TX)

Faults
and
Status

N/A

5 bytes,
first 3 bytes
alpha-numerical
4th and 5th

bytes, value of 0

or 1

Query only. Unit returns the current fault and status

codes for the Unit (hardware), Tx Traffic and Rx
Traffic, in the form abcde, where:
a = Unit fault status, b = Tx Traffic status,
c = Rx Traffic Status, d = Change in Fault Status

since last poll (0 = none, 1 = change), e = Change
in Unit Configuration since last poll (0 = none, 1 =

change)
Unit faults:
0 = No faults
1 = Power supply fault, 5 volts
2 = Power supply fault , 12 volts
3 = Power supply fault, -5 volts
4 = Power supply fault, 18 volts
5 = Power supply fault, -12 volts
6 = RAM load fail
7 = Tx synthesiser lock
8 = Rx synthesiser
9 = Power cal Checksum error
A = FPGA main chain load fail
B = Turbo FPGA load fail
C = CiM IP Module Fail
Tx Traffic status:
0 = Tx traffic OK

N/A FLT?

FLT=abcde

(see

description for
details of

arguments