beautypg.com

Mocomtech CIM-550 User Manual

Page 186

background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

CLI and Telnet Interface

CD/CIM550.IOM

160

The Redundancy Configuration page contains the following options/fields:

Menu Options/Fields

Entry

Description

Current State

Read

Only

Defines the online/offline status of the CiM.

Management IP Address,
Local Unit

Read

Only

IP Address for the Ethernet Interface for the Local Unit.
The value is set through the Ethernet Interface(fei0)
page. The Management IP Address must be on the
same subnet as the other management IP and traffic IP.

Management Subnet Prefix
Length, Local Unit

Read

Only

Subnet Prefix for the Ethernet Interface for the Local
Unit. The value is set through the Ethernet
Interface(fei0)
page. The Management Subnet Prefix
Length must be the same as the other management
prefix length and traffic prefix length. Enter the subnet
mask prefix length (range is 8..30).

Management IP address,
Redundant Unit

Read

Only

IP Address for the Ethernet Interface for the Remote
Unit. The value is set through the Ethernet
Interface(fei0)
page on the other modem in the
redundant pair. The Management IP Address must be
on the same subnet as the other management IP and
traffic IP.

Management Subnet Prefix
Length, Redundant Unit

Read

Only

Subnet Prefix for the Ethernet Interface for the Local
Unit. The value is set through the Ethernet
Interface(fei0)
page on the other modem in the
redundant pair. The Management Subnet Prefix Length
must be the same as the other management prefix
length and traffic prefix length. Enter the subnet mask
prefix length (range is 8..30).

Redundant Traffic IP
Address

T

The Traffic IP will float between the two redundant
modems and will always be active on the Online
Modem. The Redundant IP Traffic Address must be on
the same subnet as the other traffic IP.
Enter the ip address in aaa.bbb.ccc.ddd format

Redundant Traffic Subnet
Prefix Length

M

The Traffic IP will float between the two redundant
modems and will always be active on the Online
Modem. The Redundant Subnet Prefix Length must be
the same as the other traffic prefix length.
Enter the subnet mask prefix length (range is 8..30).

Force Unit Offline

F

If the modem is currently Online, this command will
force a switchover so that the redundant pair becomes
the Online modem and processes the incoming traffic.
This modem will transition from Online to Offline. Is the
modem is already Offline, then this command will be
ignored.

Save Parameters

S

This option allows a user to save the current
configuration of the CiM to permanent storage. This
configuration will be restored on each successive power
cycle of the CiM.

Exit

X

This option allows a user to exit the current menu and
return to its parent menu.