beautypg.com

Mocomtech CIM-550 User Manual

Page 102

background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

Remote Control

CD/CIM550.IOM

76

Parameter
Type

Command
(Instruction

Code and
qualifier)

Arguments for

Command or

Response to
Query

Description of arguments
(note that all arguments are ASCII numeric

codes, that is, ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query
(Instruction

Code and
qualifier)

Response to

query
(target to
controller)

than 5 events to be retrieved, the remaining
positions are padded with zeros.

Retrieve
Number of

unread
Stored

Events

N/A 2

bytes,

numerical

Query only.
Unit returns the number of Stored Events which

remain unread, in the form xx. Note: This means

unread over the remote control - viewing the stored

events from the front panel of the modem does not
affect this value. Example reply: NUE=98

N/A

NUE?

NUE=xx (see
description for

details of

arguments)

Retrieve
next 5

unread

Stored

Statistics

N/A

130 bytes

Query only
Unit returns the oldest 5 Stored Statistics which

have not yet been read over the remote control.

Reply format:

{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Su
b-body{CR}Sub-body, where Sub-body=
AA.ABB.BC.CD.Dddmmyyhhmmss,
AA.A = Minimum Eb/No during sample period.
BB.B = Average Eb/No during sample period.
C.C = Max. Tx Power Level Increase during

sample period.
D.D = Average Tx Power Level Increase during

sample period.
ddmmyyhhmmss = date/time stamp.
If there are no new events, the unit replies with

RNS? If there are less than 5 statistics to be

retrieved, the remaining positions are padded with
zeros.

N/A RNS?

RNS={CR}AA.A
BB.BC.CD.Ddd

mmyyhhmmss{

CR}AA.ABB.BC

.CD.Dddmmyyh
hmmss{CR}AA.

ABB.BC.CD.Dd

dmmyyhhmmss

{CR}AA.ABB.B
C.CD.Dddmmyy

hhmmss{CR}AA

.ABB.BC.CD.Dd

dmmyyhhmmss
(see description

for details of

arguments)

Retrieve
Number of

unread

Stored

Statistics

N/A 3

bytes,

numerical

Query only.
Unit returns the number of Stored Statistics which

remain unread, in the form xxx. Note: This means

unread over the remote control - viewing the stored

events from the front panel of the modem does not

N/A

NUS?

NUS=xxx (see
description for

details of

arguments)