beautypg.com

Gateway 840 VT-100 User Manual

Page 193

background image

188

Chapter 9: Event Logs

www.gateway.com

New Drive Rebuild Failure
SN:

xx xx xx xx xx xx A:yy

D:

zz

Rebuild has failed because
of an unrecoverable error on
the new drive. The meaning
of each field is as follows:

SN: Serial Number

A: Array number

D: Drive number in array

Typically because
of a
non-recoverable
media error, or
hardware error.

Replace new drive
and initiate a
rebuild.

Rebuild Aborted
A:

xx D:yy

A rebuild has been stopped
by the user on the indicated
drive. The meaning of each
field is as follows:

A: Array number

D: Drive number in array

A rebuild was
canceled by the
user.

No action
necessary.

Rebuild Started
SN:

xx xx xx xx xx xx A:yy

D:

zz

A rebuild has started on the
indicated drive. The
meaning of each field is as
follows:

SN: Serial Number

A: Array number

D: Drive number in array

A rebuild has
started.

No action
necessary.

Rebuild Restarted
SN:

xx xx xx xx xx xx A:yy

D:

zz

A rebuild has restarted on
the indicated drive. The
meaning of each field is as
follows:

SN: Serial Number

A: Array number

D: Drive number in array

A rebuild has
started.

No action
necessary.

Rebuild Complete A:

xx

D:

yy

A rebuild has completed on
the indicated drive. The
meaning of each field is as
follows:

A: Array number

D: Drive number in array

A rebuild has
completed.

No action
necessary.

Drive Event Messages

Description

Cause

Action