Drive events

www.gateway.com

Data Underrun
WWN:

xx xx xx xx xx xx Py

OP:

zz

The controller has detected
a data underrun from the
indicated drive. This is
caused by the controller
detecting a bad CRC in a
frame, and usually indicates
a link problem, either with
cabling or an enclosure. The
meaning of each field is as
follows:

WWN: Drive World Wide
Name

P: Drive port number

OP: SCSI command code

Signal error.

Check cabling,
Disk I/O card, and
make sure that the
hard drive is
correctly seated.

Drive Busy
SN:x

x xx xx xx xx xx Py

OP:

zz

The drive indicated has
returned a Busy status to a
command. The meaning of
each field is as follows:

SN: Serial Number

P: Drive port number

OP: SCSI command code

Drive is busy and
cannot accept any
more commands.

No action
necessary.

Drive CC
SN:

xx xx xx xx xx xx Py

OP:

zz SN:aa EXT:bb QL:cc

The drive indicated has
returned a Check Condition
status to a command. The
meaning of each field is as
follows:

SN: Serial Number

P: Drive port number

OP: SCSI command code

SN: SCSI sense key

EXT: SCSI extended sense
key

QL: SCSI extended sense
key qualifier

Typically because
of a
non-recoverable
media error,
hardware error.

No action
necessary.

Drive Event Messages

Description

Cause