PRIMERGY BX600 S2 Basic Unit
63
Preparation for Use and Operation
Updating BX600 System Components
Figure 24: Updating the management blade firmware via the web interface
Ê
Make sure that both management blades are connected to the LAN.
Ê
Enter the IP address of the
TFTP
server on which the image file for the
management blade firmware is provided.
Ê
Enter an IP address in the
Agent Update IP Address
field.
I
The IP address in the
Agent Update IP Address
field is only used tempo-
rarily, so you can enter any IP address that is not used in the LAN
segment of the server.
Ê
In the
Boot Image File Name
field, enter the name of the image file of the
management blade.
Ê
Set the value of the
TFTP Update Enable
field to
enable
.
Ê
Click
Apply
.
The firmware of the first management blade (
Master
) will now be updated
(the green LED lights up). When the update process is complete, this
management blade is defined as the
Slave
, and the second management
blade, which used to be the
Slave
, is now defined as the
Master
.
Ê
Repeat the update process for the second management blade.
After the update process for the second management blade, the original
Master-Slave
configuration is automatically restored.