PRIMERGY BX600 S2 Basic Unit

63

Preparation for Use and Operation

Updating BX600 System Components

Figure 24: Updating the management blade firmware via the web interface

Ê

Make sure that both management blades are connected to the LAN.

Ê

Enter the IP address of the

TFTP

server on which the image file for the

management blade firmware is provided.

Ê

Enter an IP address in the

Agent Update IP Address

field.

I

The IP address in the

Agent Update IP Address

field is only used tempo-

rarily, so you can enter any IP address that is not used in the LAN
segment of the server.

Ê

In the

Boot Image File Name

field, enter the name of the image file of the

management blade.

Ê

Set the value of the

TFTP Update Enable

field to

enable

.

Ê

Click

Apply

.

The firmware of the first management blade (

Master

) will now be updated

(the green LED lights up). When the update process is complete, this
management blade is defined as the

Slave

, and the second management

blade, which used to be the

Slave

, is now defined as the

Master

.

Ê

Repeat the update process for the second management blade.

After the update process for the second management blade, the original

Master-Slave

configuration is automatically restored.