The Fan Unit

The fan unit includes two redundant fans.

There are four LED indicators (

figure 96

) on the front of the fan unit for fan status

monitoring.

Figure 96: The fan unit

In addition, for each fan in the unit an error LED driven by backup capacitor is
available. These two LEDs (a) are located on the top of the fan unit to indicate
the respective defective fan. The LEDs can be activated via a pushbutton (b)
after the fan unit has been removed from the chassis.

Fan condition

Fan 1 LEDs

Fan 2 LEDs

1

(green)

2

(amber)

4

(green)

3

(amber)

Present and OK

ON

OFF

ON

OFF

Not present

OFF

OFF

OFF

OFF

Present and failed

ON

ON

ON

ON

Table 2: Fan unit indicators