PRIMERGY BX600 S2 Basic Unit
41
Installing the Hardware
Connecting External Devices
Ê
Insert the server blades into their slots (see
section “Adding a Server Blade
). Return the power supply units and fan units
to the basic unit (see
section “Replacing a Power Supply Unit” on page 142
and
section “Replacing the Fan Unit” on page 151
).
You remove the basic unit by following the above steps in reverse order:
V
CAUTION!
Please note the relevant safety instructions in
Ê
Note the slot assignment of the server blades so that you can insert them
correctly again after you have removed the basic unit from the rack.
Ê
Remove server blades, fan units and power supplies from the basic unit to
reduce weight.
Ê
Remove the four knurled screws.
Ê
Pull out the basic unit and carefully remove it from the rack.
4.4
Connecting External Devices
The external connectors of the PRIMERGY BX600 S2 basic unit are located on
the rear of the basic unit. The external connectors of the server blades are
located on the front of the basic unit. For information on these connectors see
the operating manuals of the different server blade types (see
).