Port assignment of the fc pass-thru blades, 3 port assignment of the fc pass-thru blades – FUJITSU PRIMERGY BX600 S2 User Manual
Page 117
PRIMERGY BX600 S2 Basic Unit
117
FC Pass-Thru Blade
FC Port Assignment
11.3
Port Assignment of the FC Pass-Thru
Blades
FC pass-thru blades can be installed in slots NET3 and NET4 on the rear of the
base unit. The FC pass-thru blade in slot 1 provides a bypass connection
between channel A of the installed fibre channel daughter cards and the corre-
sponding optical transceivers. The FC pass-thru blade in slot 2 provides a
connection to channel B of the installed fibre channel daughter cards.
Figure 69: Slot numbering for the Fibre Channel pass-thru blades
V
CAUTION
●
FC pass-thru blades must always be installed in slot NET3 first. This
ensures that port A of the FC daughter cards is connected if
redundant fibre channel connections are not used.
●
If Gigabit Ethernet daughter cards are installed in the server blades,
LAN switch blades (see
) or Ethernet pass-thru blades (see
) must be installed in slots NET3 and NET4.
Asynchronous balanced mode of Ethernet blades and fibre channel
blades in slots NET3 and NET4 is not permitted.
NET4
NET3