Trap overview

5.3.1

Adaptec traps (Duralink.mib)

MIB-OID: 1.3.6.1.4.1.795.3.1.2.3

This section lists Adaptec traps in alphabetical order.

5.3.2

APC traps (Powernet.mib)

MIB-OID: 1.3.6.1.4.1.318

This section lists the APC traps in alphabetical order.

Trap name

ID

Meaning

Error class

duralinkStatusTrap

1

The link status has
changed.

informational

failoverStatusTrap

1

The failover status has
changed.

informational

Table 19: Adaptec traps

Trap name

ID

Meaning

Error class

baseFanFailure

25

The base module bypass
power supply is defective.

major

batteryPackComm
Established

27

The UPS can communicate
with the external battery pack.

informational

batteryPackCommLost

26

Communication with external
battery packs interrupted.

major

bypassPowerSupply
Failure

24

The base module bypass
power supply is defective.

major

calibrationStart

28

A test to determine the battery
strength has been initiated by
the UPS.

informational

codeAuthentication
Done

32

Authentication based on the
agent code image has been
completed.

informational

Table 20: APC traps