beautypg.com

Alarm rules, 1 alarm rules – FUJITSU ServerView V6.00 User Manual

Page 39

background image

ServerView Event Manager

39

Alarm rules

4.1

Alarm rules

An alarm rule forwards alarms from various servers to one or more destinations.
A complete definition of a new alarm rule consists of the following four steps:

Defining the name of the new alarm rule (see

section "Managing alarm

rules" on page 40

).

Assigning one or more servers to the alarm rule (see

section "Assigning

servers" on page 43

). The alarm rule then only applies to alarms from these

servers.

Assigning one or more alarms to the alarm rule (see

section "Assigning

alarms" on page 47

).

Defining the response to the incoming alarms (see

section "Forwarding

alarms" on page 51

). Here you can use the standard destinations or define

your own (e.g. Execute forwarding, Mail forwarding or Mobile forwarding).

When defining a new alarm rule, you will be guided step by step through the
individual screens for setting the alarm parameters. If you are changing an
existing alarm rule you can also call up the individual dialog screens directly via
the menu tree.