beautypg.com

Servercontrol traps (sc2.mib), 18 servercontrol traps (sc2.mib) – FUJITSU ServerView V6.00 User Manual

Page 139

background image

ServerView Event Manager

139

Trap overview

5.3.18 ServerControl traps (SC2.mib)

MIB-OID: 1.3.6.1.4.1.231.2.10.2.2.10.20

This section lists ServerControl traps in alphabetical order.

Trap name

ID

Meaning

Error class

sc2TrapAcFail

2040 Mains failed in the specified

cabinet. This trap occurs
only in storage extension
cabinets without UPS or
BBU. A server has no time
to send this trap.

critical

sc2TrapBatteryVoltage
Prefail

2054 Battery is predicted to fail.

major

sc2TrapBiosSelftest
Error

2005 A critical error occurs while

BIOS selftest. Take notice
of this error to clear the
error condition.

critical

sc2TrapBootMessage
LogEntry

2102 An error message was

written into the
systemboard's message
log. This could have
happened when an error
occurred before the server
management agents were
running or any error without
a specific trap. See server
management message log
for detailed error
description.

major

sc2TrapBootRetryCount
Zero

2095 This trap will be sent when a

boot retry counter gets zero
on power up.

major

Table 42: ServerControl traps (SC2.mib)