ServerView Event Manager

141

Trap overview

sc2TrapDcFail

2041 DC power failed in the

specified cabinet.
This is the result of the
systems power-good
sensor monitoring. The
system stops if this error
occurs.

critical

sc2TrapFanAdded

2010 The indicated hot-plug fan

was inserted.

informational

sc2TrapFanCritical

2013 The indicated fan became

critical.

major

sc2TrapFanFailed

2014 The indicated fan failed.

critical

sc2TrapFanOk

2012 The indicated fan is OK

again.

informational

sc2TrapFanRemoved

2011 The indicated hot-plug fan

was removed.

informational

sc2TrapIntrusionAsserti
on

2110 The front door or housing

was opened.

major

sc2TrapIntrusionChang
ed

2112 The front door or housing

was opened or closed.

major

sc2TrapIntrusionDeass
ertion

2111 The front door or housing

was closed.

informational

sc2TrapMemErrorModul
eFailing

2069 A memory module failed.

major

sc2TrapMemErrorModul
ePrefail

2068 A memory module is

predicted to fail (prefailure).

major

sc2TrapMemErrorModul
eReplaced

2070 A memory module failed

and was replaced by a hot-
spare module.

major

Trap name

ID

Meaning

Error class

Table 42: ServerControl traps (SC2.mib)