FUJITSU ServerView V6.00 User Manual
Page 143
ServerView Event Manager
143
Trap overview
sc2TrapRedundantFanF
ailed
2015 The indicated redundant
fan failed.
major
sc2TrapRedundantPow
erSupplyFailed
2035 One redundant hot-replace
power supply failed.
major
sc2TrapServerShutdow
n
2093 This trap will be sent before
a server will switch off.
informational
sc2TrapSevereSystemE
rror
2006 The system was restarted
after a severe problem. See
server management
message log (recovery log)
for detailed information.
critical
sc2TrapShutdownCanc
elled
2094 This trap will be sent if a
pending server shutdown
was canceled by the user.
informational
sc2TrapTempCritical
2022 The temperature of the
indicated sensor is out of
tolerance range. The
system will shut down and
power off if shutdown is
enabled.
critical
sc2TrapTempOk
2020 The temperature of the
indicated sensor has
decreased to the normal
level.
informational
sc2TrapTempSensorOk
2023 The indicated broken
temperature sensor is OK
again.
informational
sc2TrapTempSensorBro
ken
2024 The indicated temperature
sensor is broken.
major
sc2TrapTempWarning
2021 The temperature of the
indicated sensor has
reached the warning level.
major
sc2TrapTest
2000 Test trap to verify trap
connection.
informational
Trap name
ID
Meaning
Error class
Table 42: ServerControl traps (SC2.mib)