Threshold traps (trap.mib), 23 threshold traps (trap.mib) – FUJITSU ServerView V6.00 User Manual
Page 163
ServerView Event Manager
163
Trap overview
5.3.23 Threshold traps (Trap.mib)
MIB-OID: 1.3.6.1.4.1.231
This section lists threshold traps in alphabetical order.
Trap name
ID
Meaning
Error class
sniInvDeltaTrap
Underflow
131 DELTA threshold underflow.
This trap indicates, that one
of the polled variables has
left the interval specified by
the user. The variable will
be given in the
sniInvPollAlarm field.
informational
sniInvPollDeltaExceed
130 DELTA threshold exceeded.
This trap indicates, that one
of the polled variables has
left the interval specified by
the user. The variable will
be given in the
sniInvPollAlarm field.
informational
sniInvPollTrapExceed
128 Threshold exceeded. This
trap indicates, that one of
the polled variables has left
the interval specified by the
user. The variable will be
given in the sniInvPollAlarm
field.
informational
sniInvPollTrapUnderflow
129 Threshold underflow. This
trap indicates, that one of
the polled variables has left
the interval specified by the
user. The variable will be
given in the sniInvPollAlarm
field.
informational
sniInvTrapInvalid
132 Threshold has become
invalid.
informational
Table 49: Threshold traps