FUJITSU ServerView V6.00 User Manual
Page 149

ServerView Event Manager
149
Trap overview
tapeAlertTrap12
12
You have tried to load a
cartridge of a type which is
not supported by this drive.
informational
tapeAlertTrap13
13
The operation has failed
because the tape in the
drive has snapped:
1. Discard the old tape.
2. Restart the operation
with a different tape.
critical
tapeAlertTrap14
14
The operation has failed
because the tape in the
drive has snapped:
1. Do not attempt to extract
the tape cartridge.
2. Call the tape drive
supplier helpline.
critical
tapeAlertTrap15
15
The memory in the tape
cartridge has failed, which
reduces performance. Do
not use the cartridge for
further backup operations.
minor
tapeAlertTrap16
16
The operation has failed
because the tape cartridge
was manually ejected while
the tape drive was actively
writing or reading.
critical
tapeAlertTrap17
17
You have loaded a cartridge
of a type that is read-only in
this drive. The cartridge will
appear as write-protected.
minor
tapeAlertTrap18
18
The directory on the tape
cartridge has been
corrupted. File search
performance will be
degraded.
minor
Trap name
ID
Meaning
Error class
Table 45: Tape traps