Making trap settings, 10 making trap settings – FUJITSU ServerView V6.00 User Manual
Page 77

ServerView Event Manager
77
Making trap settings
4.10
Making trap settings
If you have selected
Station
for the forwarding, the
New Station Configuration
window opens. In this window you can use the
Station Settings
and
Time Model
Settings
tabs to make all necessary settings for trap forwarding.
Station Settings
tab
The
Station Settings
tab offers fields for the trap settings, some of which
already contain predefined settings.
The input fields in the
Station Settings
window have the following
meanings:
Name
Meaning
Station Name Name of the station to which the traps are to be
forwarded.
If you want to modify the trap settings for an existing trap
forwarding (see
Edit
button,
), this field contains the already
assigned name and is disabled.
Community
Name of the community to which the traps are to be
forwarded.
The default value is
public.
Time Model
Time model indicating when an alarm is to be
forwarded.
Select a predefined time model from the drop-down list.
You can set your own time model via the
Time Model
Settings
tab.
IP Address
Internet protocol address
Table 16: Input fields in the Station Settings window