beautypg.com

FUJITSU ServerView V6.00 User Manual

Page 142

background image

142

ServerView

Event

Manager

Trap overview

sc2TrapMessageLogFul
l

2100 The System Event Log

(message log) is full. No
more messages can be
logged. This trap will not
occur on wrap-around log
types.

minor

sc2TrapMessageLogWa
rning

2101 The warning threshold for

the number of System
Event Log entries has been
exceeded.

minor

sc2TrapOnBattery

2042 The UPS is operating on

battery power or the power
supply is drawing current
from the backup battery unit
(BBU). This trap is
persistent and is resent at
one minute intervals until
the mains returns or the
system is switched off.

critical

sc2TrapOnMains

2043 The mains voltage returned

after a power failure.

informational

sc2TrapPowerOffTimeR
eached

2092 Power off time reached.

informational

sc2TrapPowerSupplyAd
ded

2030 One hot-replace power

supply was added.

informational

sc2TrapPowerSupplyCri
tical

2033 Power supply status

became critical.

critical

sc2TrapPowerSupplyFai
led

2034 One hot-replace power

supply failed.

major

sc2TrapPowerSupplyOk 2032 Power supply is working

again.

informational

sc2TrapPowerSupplyRe
dundancyLost

2036 Power supply redundancy

id no longer available.

minor

sc2TrapPowerSupplyRe
moved

2031 One hot-replace power

supply was removed.

informational

Trap name

ID

Meaning

Error class

Table 42: ServerControl traps (SC2.mib)