Trap overview

sieScUserAuthentication
Failure

664 User authentication failure

is detected via PPP, FTP,
HTTP or telnet.

major

sniScCpuSpeedChanged 656 CPU speed has changed

because of temperature
problems.

informational

sniScFanAdded

653 The indicated hot-plug fan

was inserted.

informational

sniScFanRemoved

654 The indicated hot-plug fan

was removed.

informational

sniScPowerSupply
RedundancyLost

671 Power supply redundancy

no longer available.

minor

sniScRedundant
FanFailed

648 The indicated redundant

fan failed.

major

sniScRedundant
PowerSupplyFailed

649 One redundant hot-replace

power supply failed.

major

sniScShutdown
Cancelled

655 A pending server shutdown

was canceled by the user.

informational

sniScVoltageOk

650 Power supply voltage is

within normal range again.

informational

sniScVoltageTooHigh

652 Power supply voltage is too

high.

critical

sniScVoltageTooLow

651 Power supply voltage is too

low.

critical

svCommunication
Established

636 Communication with the

server management
controller was established.

informational

svCommunicationFailure

610 Communication with the

server management
controller was interrupted.

critical

tempCritical

604 The temperature has

reached a critical level.

critical

tempOk

602 The temperature is within

normal range.

informational

Trap name

ID

Meaning

Error class

Table 41: ServerControl traps (SC.mib)