FUJITSU ServerView V6.00 User Manual
Page 136
136
ServerView
Event
Manager
Trap overview
sieScUserAuthentication
Failure
664 User authentication failure
is detected via PPP, FTP,
HTTP or telnet.
major
sniScCpuSpeedChanged 656 CPU speed has changed
because of temperature
problems.
informational
sniScFanAdded
653 The indicated hot-plug fan
was inserted.
informational
sniScFanRemoved
654 The indicated hot-plug fan
was removed.
informational
sniScPowerSupply
RedundancyLost
671 Power supply redundancy
no longer available.
minor
sniScRedundant
FanFailed
648 The indicated redundant
fan failed.
major
sniScRedundant
PowerSupplyFailed
649 One redundant hot-replace
power supply failed.
major
sniScShutdown
Cancelled
655 A pending server shutdown
was canceled by the user.
informational
sniScVoltageOk
650 Power supply voltage is
within normal range again.
informational
sniScVoltageTooHigh
652 Power supply voltage is too
high.
critical
sniScVoltageTooLow
651 Power supply voltage is too
low.
critical
svCommunication
Established
636 Communication with the
server management
controller was established.
informational
svCommunicationFailure
610 Communication with the
server management
controller was interrupted.
critical
tempCritical
604 The temperature has
reached a critical level.
critical
tempOk
602 The temperature is within
normal range.
informational
Trap name
ID
Meaning
Error class
Table 41: ServerControl traps (SC.mib)