beautypg.com

FUJITSU ServerView V6.00 User Manual

Page 34

background image

34

ServerView

Event

Manager

iRMC S2/S3 SEL Entries and SC2 MIB Traps

150031

Battery voltage ’BATT
XY’ low warning: %
Volt

Battery voltage
’BATT XY’ in cabinet
XY at server XY:
Battery is predicted
to fail in near future.

2054 sc2TrapBattery

VoltagePrefail

190003

’DIMM XY’ Memory:
Uncorrectable error
(ECC)

Uncorrectable
memory error at
module ’DIMM XY’
in cabinet XY of
server XY.

2065 sc2Trap

Uncorrectable
MemError
Module

190040

’DIMM XY’:
Uncorrectable Parity
memory error

190007

Memory:
Uncorrectable error
(ECC)

Uncorrectable
memory error in
cabinet XY of server
XY.

2067 sc2Trap

Uncorrectable
MemError

190008

Correctable memory
error disabled

Too many
correctable memory
errors in cabinet XY
at server XY. Error
logging was
disabled. If logging
was disabled and
not automatically
enabled again, you
have to reboot your
server to enable
memory error
logging again. If
logging is disabled,
prefailure detection
is also not active!

2071 sc2TrapMem

ErrorLogging
Disabled

Error
code

iRMC S2/S3 SEL
entry

Trap text

Trap
no.

Trap name

Table 4: iRMC S2/S3 SEL entry - SC2 MIB trap