beautypg.com

FUJITSU ServerView V6.00 User Manual

Page 127

background image

ServerView Event Manager

127

Trap overview

fanFailureTrap

5

The fan in the specified
location has failed. Replace
fan.

major

fanInformationTrap

6

The fan in the specified
location was recovered.

informational

lunFailureTrap

16

The LUN has failed and is
off-line. Possible cause is
too many failed disk drives
that make up the LUN, the
OS can no longer
communicate with the LUN
for other reasons.

critical

lunInformationTrap

19

A LUN has become optimal
due to successful
completion of the
reconstruction process.

informational

lunReconstructTrap

17

The LUN has started the
reconstruction process but
is available for normal use.
Possible causes are an
available disk drive was
created as a spare to be
inserted into the set, an
existing spare was
automatically added to the
set for reconstruction upon
failure of a member disk
device.

minor

lunReducedTrap

18

A LUN has become
degraded due to a member
disk device failure. Replace
the failed disk device; add a
spare to the system to
cause a reconstruct.

major

Trap name

ID

Meaning

Error class

Table 38: PXRE traps