beautypg.com

FUJITSU ServerView V6.00 User Manual

Page 32

background image

32

ServerView

Event

Manager

iRMC S2/S3 SEL Entries and SC2 MIB Traps

07000A ’PSU XY’: Power

supply critical
temperature

Temperature at
power supply ’PSU
XY’ in cabinet XY of
server XY has
reached the critical
level.

2037 sc2TrapPower

SupplyCritical
Temperature

07000F ’PSU XY’: Power

supply fan prefailure

Fan failure is
predicted at power
supply ’PSU XY’ in
cabinet XY of server
XY.

2038 sc2TrapPower

SupplyFan
Failure
Prediction

0C0004 ’CPU XY’: CPU

internal error (IERR)

Internal error (IERR)
occurred on CPU
’CPU XY’ in cabinet
XY of server XY.

2082 sc2TrapCpu

Ierr

0C0021 ’CPU XY’:

Uncorrected CPU
Machine Check
Architecture (MCA)
error

0C0007 ’CPU XY’: CPU clock

automatically
throttled

CPU speed at server
XY changed to XY
percent of its
maximum speed.

2080 sc2TrapCpu

Speed
Changed

0C0017 ’CPU XY’: CPU

failure predicted

CPU failure is
predicted for CPU
’CPU XY’ in cabinet
XY.

2081 sc2TrapCpu

Prefail

0C000B ’CPU XY’: CPU

disabled

CPU ’CPU XY’ in
cabinet XY of server
XY is disabled.

2083 sc2TrapCpu

Disabled

Error
code

iRMC S2/S3 SEL
entry

Trap text

Trap
no.

Trap name

Table 4: iRMC S2/S3 SEL entry - SC2 MIB trap