beautypg.com

FUJITSU ServerView V6.00 User Manual

Page 30

background image

30

ServerView

Event

Manager

iRMC S2/S3 SEL Entries and SC2 MIB Traps

040003

’FAN XY’: Redundant
fan failed

The redundant fan
’FAN XY’ failed in
cabinet XY of server
XY. System can
become critical if
another fan in this
group fails.

2015 sc2Trap

RedundantFan
Failed

040004

’FAN XY’: Fan
removed

Fan ’FAN XY’ was
removed from
cabinet XY of server
XY.

2011 sc2TrapFan

Removed

050001

’Temp XY’:
Temperature OK

Temperature at
sensor ’Temp XY’ in
cabinet XY of server
XY is within normal
range.

2020 sc2TrapTemp

Ok

050016

’Temp XY’:
Temperature warning

Temperature at
sensor ’Temp XY’ in
cabinet XY of server
XY has reached the
warning level.

2021 sc2TrapTemp

Warning

050017

’Temp XY’:
Temperature critical

Temperature at
sensor ’Temp XY’ in
cabinet XY of server
XY has reached the
critical level.

2022 sc2TrapTemp

Critical

070000

’PSU XY’: Power
supply removed

Power supply ’PSU
XY’ in cabinet XY at
server XY was
removed.

2031 sc2TrapPower

Supply
Removed

Error
code

iRMC S2/S3 SEL
entry

Trap text

Trap
no.

Trap name

Table 4: iRMC S2/S3 SEL entry - SC2 MIB trap