beautypg.com

FUJITSU ServerView V6.00 User Manual

Page 31

background image

ServerView Event Manager

31

iRMC S2/S3 SEL Entries and SC2 MIB Traps

070001

’PSU XY’: Power
supply OK

Power supply ’PSU
XY’ in cabinet XY at
server XY was
added.

2030 sc2TrapPower

SupplyAdded

Power supply ’PSU
XY’ in cabinet XY at
server XY is working
again.

2032 sc2TrapPower

SupplyOk

070002

’PSU XY’: Power
supply failed

Power supply ’PSU
XY’ in cabinet XY at
server failed.

2034 sc2TrapPower

SupplyFailed

Redundant power
supply ’PSU XY’ in
cabinet XY at server
XY failed. System
can become critical
if another power
supply fails.

2035 sc2Trap

Redundant
PowerSupply
Failed

070003

’PSU XY’: Redundant
power supply AC
failed

AC failure in cabinet
XY of server XY.

2040 sc2TrapAcFail

070005

Power unit: power
supply redundancy
lost

Power supply
redundancy in
cabinet XY at server
XY lost. System will
become critical if a
power supply fails.

2036 sc2TrapPower

Supply
Redundancy
Lost

070009

’PSU XY’: Redundant
power supply DC
failed

DC power failure in
cabinet XY of server
XY.

2041 sc2TrapDcFail

070010

’PSU XY’: Power
supply fan failure

Fan failure at power
supply ’PSU XY’ in
cabinet XY of server
XY.

2039 sc2TrapPower

SupplyFan
Failure

Error
code

iRMC S2/S3 SEL
entry

Trap text

Trap
no.

Trap name

Table 4: iRMC S2/S3 SEL entry - SC2 MIB trap