FUJITSU ServerView V6.00 User Manual
Page 157
![background image](/manuals/104593/157/background.png)
ServerView Event Manager
157
Trap overview
tapeAlertTrap266
266 The voltage supply to the
library exceeds
specifications. There is a
potential problem with the
power supply or failure of a
redundant power supply.
critical
tapeAlertTrap267
267 A cartridge has been left in
a drive inside the library by
a previous hardware fault:
1. Insert an empty
magazine to clear the
fault.
2. If the fault does not
clear, turn the library off
and then on again.
3. If the problem persists,
call the library supplier
helpline.
critical
tapeAlertTrap268
268 There is a potential problem
with a drive ejecting
cartridges short or with the
library mechanism picking a
cartridge from a slot. If the
problem persists, call the
library supplier helpline.
minor
tapeAlertTrap269
269 There is a potential problem
with the library mechanism
placing a cartridge into a
slot. If the problem persists,
call the library supplier
helpline.
minor
tapeAlertTrap270
270 There is a potential problem
with a drive or the library
mechanism loading
cartridges, or an
incompatible cartridge.
minor
Trap name
ID
Meaning
Error class
Table 45: Tape traps