FUJITSU ServerView V6.00 User Manual

Page 148

background image

148

ServerView

Event

Manager

Trap overview

tapeAlertTrap6

6

The tape is from a faulty
batch or the tape drive is
faulty:

1. Use a good tape to test

the drive.

2. If the problem persists,

call the tape drive
supplier helpline.

critical

tapeAlertTrap7

7

The tape cartridge has
reached the end of its
calculated useful life:

1. Copy any data you need

to another tape

2. Discard the old tape.

minor

tapeAlertTrap8

8

The tape cartridge is not
data-grade. Any data you
back up to the tape is at
risk. Replace the cartridge
with a data-grade tape.

minor

tapeAlertTrap9

9

You are trying to write to a
write-protected cartridge.
Remove the write-
protection or use another
tape.

critical

tapeAlertTrap10

10

You cannot eject the
cartridge because the tape
drive is in use. Wait until the
operation is complete
before ejecting the
cartridge.

informational

tapeAlertTrap11

11

The tape in the drive is a
cleaning cartridge. If you
want to back up or restore,
insert a data-grade tape.

informational

Trap name

ID

Meaning

Error class

Table 45: Tape traps