beautypg.com

Replicating the setup, Copying to single workstation, Copying to multiple workstations – HP XW3400 User Manual

Page 40

background image

If the system successfully reprograms the ROM, the system will automatically power off.

4

.

Remove the removable media used to upgrade the BIOS.

5

.

Turn the power on to restart the workstation.

Replicating the setup

The following procedures give an administrator the ability to easily copy one setup configuration to other

workstations of the same model. This allows for faster, more consistent configuration of multiple

workstations.

NOTE:

Both procedures require a diskette drive or a supported USB flash media device, such as an HP

Drive Key.

Copying to single workstation

CAUTION:

A setup configuration is model-specific. File system corruption may result if source and target

workstations are not the same model. For example, do not copy the setup configuration from a xw3400

Workstation to a xw3400 Workstation.

1

.

Select a setup configuration to copy. Turn off the workstation. If you are in Windows, click

Start > Shut Down > Shut Down.

2

.

If you are using a USB flash media device, insert it now.

3

.

Turn on the workstation.

4

.

As soon as the workstation is turned on, press

F10

when the monitor light turns green to enter

Computer Setup. Press

Enter

to bypass the title screen, if necessary.

NOTE:

If you do not press

F10

at the appropriate time, you must restart the workstation and again

press

F10

when the monitor light turns green to access the utility.

5

.

If you are using a diskette, insert it now.

6

.

Click File > Replicated Setup > Save to Removable Media. Follow the instructions on the

screen to create the configuration diskette or USB flash media device.

7

.

Turn off the workstation to be configured and insert the configuration diskette or USB flash media

device.

8

.

Turn on the workstation to be configured.

9

.

As soon as the workstation is turned on, press

F10

when the monitor light turns green to enter

Computer Setup. Press

Enter

to bypass the title screen, if necessary.

10

.

Click File > Replicated Setup > Restore from Removable Media, and follow the instructions

on the screen.

11

.

Restart the workstation when the configuration is complete.

Copying to multiple workstations

CAUTION:

A setup configuration is model-specific. File system corruption may result if source and target

workstations are not the same model. For example, do not copy the setup configuration from a xw3400

Workstation to a xw3400 Workstation.

30 Chapter 4 Desktop management

ENWW