Activity
Beeps
Possible Cause
Recommended Action
Red Power LED flashes nine
times, once every second,
followed by a two second
pause. Beeps stop after fifth
iteration but LEDs continue until
problem is solved.
9
System powers on but is
unable to boot.
1
.
Check that the voltage selector, located on the
rear of the power supply (some models), is set
to the appropriate voltage. Proper voltage
setting depends on your region.
2
.
Replace the system board.
3
.
Replace the processor.
Red Power LED flashes ten
times, once every second,
followed by a two second
pause. Beeps stop after fifth
iteration but LEDs continue until
problem is solved.
10
Bad option card.
1
.
Check each option card by removing the card
(one at a time if multiple cards), then power
on the system to see if fault goes away.
2
.
Once a bad card is identified, remove and
replace the bad option card.
3
.
Replace the system board.
System does not power on and
LEDs are not flashing.
None
System unable to power
on.
Press and hold the power button for less than 4
seconds. If the hard drive LED turns green, the
power button is working correctly. Try the
following:
1
.
Check that the voltage selector (some models),
located on the rear of the power supply, is set
to the appropriate voltage. Proper voltage
setting depends on your region.
2
.
Replace the system board.
OR
Press and hold the power button for less than 4
seconds. If the hard drive LED does not turn on
green then:
1
.
Check that the unit is plugged into a working
AC outlet.
2
.
Open hood and check that the power button
harness is properly connected to the system
board.
3
.
Check that both power supply cables are
properly connected to the system board.
4
.
Check to see if the 5V_aux light on the system
board is turned on. If it is turned on, then
replace the power button harness. If the
problem persists, replace the system board.
5
.
If the 5V_aux light on the system board is not
turned on, remove the expansion cards one at
a time until the 5V_aux light on the system
board turns on. It the problem persists,
replace the power supply.