A
PPENDIX
A: A
UTHENTICATION
O
PERATIONS
A
CTIVE
D
IRECTORY
A
GENT
8
E
6 T
ECHNOLOGIES
, R3000 I
NTERNET
F
ILTER
A
UTHENTICATION
U
SER
G
UIDE
259
• “Enable NetWkstaUserEnum workstation probes”: By
default, this probe process is selected to run.
• Minimum probe interval: By default, 5 minutes
displays as the interval of time in which the selected
probe type(s) will probe workstations.
• “Auto-logoff unresponsive workstations”: By default,
this checkbox is checked, indicating that any worksta-
tion a probe fails to find will be automatically logged off
in the activity log.
• Other servers: By default, this field is blank. If there
are servers to be probed on the network, enter the host
names of all servers, including a space between each
name. Any server listed in this field will be assigned a
host—unless a satellite host has already been
assigned using the Satellite Agent Configuration dialog
box, accessible via the Agent hosts page.
NOTE: Domain controllers should not be added to the Other
servers list.