[Setting]

Setting

39

0 to 10000

<0>

ms

Bumping detection

time

Specify home position recognition time for bumping homing.

3A

0 to 100

<0>

%

Torque limit for

bumping homing

Specify a homing torque limit for bumping homing.

3B

0 to 100

<0>

Homing Z-phase

count setting

Specify a Z phase at which the machine stops if the machine stops at the Z

phase when returning to its home position. If “0” is specified, the machine

stops at the first Z phase. (The same operation when “1” is specified.)

38

*

0 to 1

<0>

Homing skip

If “1” is specified, a step operation can be performed without homing. In
this case, a position when the power supply has turned on is defined as a

home position.


If the absolute mode (17-bit absolute encoder is used and SV.Pr08 (abso-
lute encoder setting) is 0.2) is enabled, “Homing not required” is specified
regardless of this parameter.

Setup value

<0>

1

Description

Homing required

Homing not required

37

0 to 1

<0>

Home complete

type

Select an operation when homing has completed.

Setup value

<0>

1

Description

Set a current position to “- home offset” when the machine

has returned to its home position.

The machine moves according to the home offset when

homing has completed.

36

0 to 7

<0>

Homing type

Select how to perform the homing.

Setup value

<0>

1

2

3

4

5

6

7

Description

Home sensor + Z phase (based on the front end)

Home sensor (based on the front end)

Home sensor + Z phase (based on the rear end)

Limit sensor + Z phase

Limit sensor

Z phase homing

Bumping homing

Data set

35

0 to 1

<0>

Homing direction

Specify an operating direction of homing.

Setup value

<0>

1

Description

Detects a home position in a positive direction.

Detects a home position in a negative direction.

16-bit

positioning

PrNo.

Standard default : < >

Setup

range

Unit

Title

Function/Content

Parameters for Jog operation

41

0 to 6000

<0>

r/min

Jog speed (high)

Specify a speed for a high-speed jog operation.

42

0 to 10000

<0>

ms

Acceleration

setting in jog

operation

Specify acceleration for a jog operation.
Specify an acceleration time in a range between 0 to 3000 [r/min].
* There is a maximum of 10% difference between a calculation value in the

setup and the actual acceleration time.

43

0 to 1000

<0>

ms

Setting of S-shaped

acceleration in jog

operation

Specify S-shaped acceleration for a jog operation.
Specify the S-shaped control time during acceleration time. For details, refer
to page 131.
If “0” is specified, the linear acceleration control is enabled.

40

0 to 6000

<0>

r/min

Jog speed (low)

Specify a speed for a low-speed jog operation.

A low-speed jog can be started only from the console.
For a jog operation with a specified point, a set value for a high-speed jog
is used.

16-bit

positioning

PrNo.

Standard default : < >

Setup

range

Unit

Title

Function/Content