beautypg.com

Servo-on/off action while the motor is in motion, Operation setting, Caution – Panasonic MINAS A4P Series User Manual

Page 135

background image

135

[Operation Setting]

Operation

Setting

Servo-ON/OFF Action While the Motor Is at Stall (Servo-Lock)

Caution

*1. t1 will be determined by SV.Pr6A setup value.
*2. For the dynamic brake action at Servo-OFF, refer to an explanation of SV.Pr69, "Sequence at Servo-

OFF ("Parameter setup" at each control mode) as well.

*3. Servo-ON will not be activated until the motor speed falls below approx. 30r/min.
*4. Once the servo turns off, the current position output (P1OUT to P32OUT: CN X5 Pin 29, 30, 31, 32, 33

and 34) is held to be unchanged until the next point operation is completed.

Servo-ON/OFF Action While the Motor Is in Motion

(Timing at emergency stop or trip. Do not repeat this sequence. During the normal operation, stop the motor,
then make Servo-ON/OFF action.)

Caution

*1. t1 will be a shorter time of either the setup value of SV.Pr6B or elapsing time for the motor speed to fall

below 30r/min.

*2. For a dynamic brake operation during servo off and a motor operation state during deceleration, refer to

the explanation of SV.Pr69 (sequence at servo off) also.

*3. For the action of dynamic brake at alarm occurrence, refer to an explanation of Pt69, "Sequence at

Servo-OFF ("Parameter setup" at each control mode) as well.

*4. Once the servo turns off, the current position output (P1OUT to P32OUT: CN X5 Pin 29, 30, 31, 32, 33

and 34) is held to be unchanged until the next point operation is completed.

OFF

OFF

ON

engaged *2

released

not-energized

engaged *2

*4

not-energized *4

energized

engaged

(OFF)

engaged

(OFF)

released (ON)

engaged (OFF)

released (ON)

No servo-ON until the motor speed
falls below approx. 30r/min.

approx.1 to 5ms

approx.40ms

Setup value of

SV.Pr6B

when setup
value of SV.Pr6B
is shorter,

Setup value of

SV.Pr6B

approx.2ms

approx.30r/min

Dynamic brake

Motor energization

Motor rotational
speed

Motor rotational speed

servo validated

Brake release output
(BRK-OFF)

Servo-ON input
(SEV-ON)

when setup
value of SV.Pr6B
is shorter,

Motor rotational

speed

approx.30r/min

Motor rotational

speed

approx.30r/min

t1 *1

t1 *1

Dynamic brake

Motor energization

Brake release output
(BRK-OFF)

Servo-ON input
(SEV-ON)

approx.40ms

approx.2ms

approx.2ms

1 to 5ms

t1 *1

released (ON)

OFF

not-energized

ON

released

energized

engaged (OFF)

OFF

engaged *2

engaged *3

not-energized