beautypg.com

System configuration and wiring, Cautions, Wiring to the external scale, connector, cn x7 – Panasonic MINAS A4P Series User Manual

Page 40

background image

40

System Configuration and Wiring

Cautions

(1) Following external scale can be used for full-closed control.

• AT500 series by Mitutoyo (Resolution 0.05[

µ

m], max. speed 2[m/s])

• ST771 by Mitutoyo (Resolution 0.5[

µ

m], max. speed 2[m/s])

(2) Recommended external scale ratio is 1/20

If you set up the external scale ratio to smaller value than 50/position loop gain (SV.Pr10 and 18), you
may not be able to control per 1 pulse unit. Setup of larger scale ratio may result in larger noise.

Wiring to the External Scale, Connector, CN X7

Wire the signals from the external scale to the external scale connector, CN X7.

1) Cable for the external scale to be the twisted pair with bundle shielding and to having the twisted core

wire with diameter of 0.18mm

2

.

2) Cable length to be max. 20m. Double wiring for 5V power supply is recommended when the wiring

length is long to reduce the voltage drop effect.

3) Connect the outer film of the shield wire of the external scale to the shield of the junction cable. Also

connect the outer film of the shield wire to the shell (FG) of CN X7 of the driver without fail.

4) Separate the wiring to CN X7 from the

power line (L1, L2, L3, L1C(r), L2C(t),
U, V. W, ) as much as possible (30cm
or more). Do not pass these wires in
the same duct, nor bundle together.

5) Do not connect anything to the vacant

pins of CN X7.

6) Cut away the driver's CN X7 cover.

Content

EX5V

EX0V

EXPS

EXPS

FG

Connector

PinNo.

1

2

5

6

Case

Application

Power supply output

for external scale

I/F of external scale signals

(serial signal)

Frame ground

External scale side

External scale unit

Detection head

Junction cable

Servo driver

EX5V

EX0V

EX5V

EX0V

EX5V

EX0V

EX5V

CN X7

EX0V

EXPS

EXPS

3

1

4

2

11

13

1

2

+5V

0V

3

4

5

6

7

8

15

Regulator

HDAB-15P

(by Hirose Electric Co.)

HDAB-15S

(by Hirose Electric Co.)

55100-0600

(by Molex Inc.)

Twisted pair

EXPS

FG

EXPS

X6

X7

Please cut it out
with nippers etc.

Wiring to the Connector, CN X7 (Connection to External Scale)

Power supply for the external scale shall be prepared by customer, or use the following power supply output
for the external scale (250mA or less).


EXOV of the external scale power supply output is connected to the control circuit ground which is
connected to the Connecter, CN X5.

Do not connect anything to other Pin numbers descried in the above table (Pin-3 and 4).