HP 250C User Manual
Page 189

330
350C
Media Type
Replot
Print Quality
Form Feed
Roll/Sheet
Continue
Plotting
8Ć55
Troubleshooting
C4699Ć90000
Clearing the EEROM for the DesignJet 330 and 350C
If you clear the calibration parameters, you will then need to perform the plotter
calibrations. (Details
' chapter 7.) Clearing the EEROM also resets the factory
spittoon value to 0% used. Keep in mind that the value printed on the service
configuration plot may greatly underestimate the amount of ink in the spittoon.
C A U T I O N
Clearing Just the Benchrun and Calibration Parameters
1 Switch the plotteroff.
2 While holding both the
Replot
and
Media Type
keys down,
switch the plotteron.
3 Once the the LEDs begin to light up one by one, release the
Replot
and
Media Type
keys.
Clearing Just the UserĆDefined SetupParameters
1 Switch the plotteroff.
2 While holding both the
Form Feed
and
Print Quality
keys
down, switch the plotteron.
3 Once the the LEDs begin to light up one by one, release the
Form Feed
and
Print Quality
keys.
Clearing All Parameters
1 Switch the plotteroff.
2 While holding both the
Roll/Sheet
and
Continue Plotting
keys down, switch the plotteron.
3 Once the the LEDs begin to light up one by one, release the
Roll/Sheet
and
Continue Plotting
keys.