beautypg.com

HP 250C User Manual

Page 189

background image

330

350C

Media Type

Replot

Print Quality

Form Feed

Roll/Sheet

Continue
Plotting

8Ć55

Troubleshooting

C4699Ć90000

Clearing the EEROM for the DesignJet 330 and 350C

If you clear the calibration parameters, you will then need to perform the plotter
calibrations. (Details

' chapter 7.) Clearing the EEROM also resets the factory

spittoon value to 0% used. Keep in mind that the value printed on the service
configuration plot may greatly underestimate the amount of ink in the spittoon.

C A U T I O N

Clearing Just the Benchrun and Calibration Parameters

1 Switch the plotteroff.
2 While holding both the

Replot

and

Media Type

keys down,

switch the plotteron.

3 Once the the LEDs begin to light up one by one, release the

Replot

and

Media Type

keys.

Clearing Just the UserĆDefined SetupParameters

1 Switch the plotteroff.
2 While holding both the

Form Feed

and

Print Quality

keys

down, switch the plotteron.

3 Once the the LEDs begin to light up one by one, release the

Form Feed

and

Print Quality

keys.

Clearing All Parameters

1 Switch the plotteroff.
2 While holding both the

Roll/Sheet

and

Continue Plotting

keys down, switch the plotteron.

3 Once the the LEDs begin to light up one by one, release the

Roll/Sheet

and

Continue Plotting

keys.