beautypg.com

HP 250C User Manual

Page 173

background image

230

250C

8Ć39

Troubleshooting

C4699Ć90000

Carriage Test for the DesignJet 230 and 250C

This tests the operation of the carriage sensor and the connection between the carriage flex

circuit and the cartridges.

1 Position the sensorovera white surface. (Simply place a piece of

white paperunderthe sensor.)

2 In service mode 1, press

Carriage Test

.

The plotter varies the LED intensity between 255 and 0.
The plotter tests the connection between the carriage flex circuit

and the cartridges by getting the cartridge identification and

checking the electrical continuity for all nozzles.
Status. During the test, the

Cartridges

and

Error

LEDs turn on (steady) if the

carriage test has not found an error. If the test fails, one or both of these LEDs flash as

indicated below:

Both OK

Sensor Failed

Flex-Circuit

Connection Failed

Both Failed

Output to the Serial Port (Viewing Output

'

8-36)

Error code:

If an error has occurred in the sensor test, this code specifies more
precisely what has gone wrong. Include this information in the
report to your HP Response Center, if the problem cannot be fixed.

Pen 0 = Cyan; Pen 1 = Magenta; Pen 2 = Yellow; Pen 3 = Black.

Sensor sensitivity:

The sensitivity measured during the test. The figures should vary
from 255 to 0. Failure occurs when the sensitivity does not vary
(for example, it stays at 255).

Pen ID:

If a pen does not fail, the plotter outputs the pen ID.

3 The test continuously repeats itself until you

press the

Shift

key.

Carriage

Test

Shift