HP 250C User Manual
Page 158
8Ć24 Troubleshooting
C4699Ć90000
Filename
Failure
(andmost frequent causes)
Line Number
Filename
Failure
(andmost frequent causes)
Firmware
A.01.00
testmode.c
3684
Error in DRAM data test:
D Faulty carriage.
testmode.c
3691
Error in DRAM addresses test:
D Faulty electronics module.
testmode.c
3698
Unknown DRAM error:
D Faulty electronics module.
testmode.c
3722
Error in the test of the inĆbuilt ROM and
ROM SIMM performedat powerĆon:
D ROM SIMM badly seated.
D Faulty ROM SIMM.
D Faulty electronics module.
testmode.c
3733
Error in the test of the maskedROM:
D Faulty electronics module.
main.c
238
Failure in cartridge initialization:
D Faulty or badly connected trailing cable.
main.c
381
Failure in fan connection test:
D Faulty electronics module.
main.c
230 or
354
Model ID configuration incorrect.
Reconfigure the plotter ' page 8Ć28.
selftest.c
1502
Failure in test to actuate inĆbuilt ROM or
ROM SIMM:
D ROM SIMM badly seated.
D Faulty ROM SIMM.
D Faulty electronics module.
selftest.c
1506
Failure in maskedĆROM test:
D Faulty electronics module.
selftest.c
1513
Failure in mainĆPCA DRAM test:
D Faulty electronics module.