230

250C

8Ć49

Troubleshooting

C4699Ć90000

Service Configuration Plot for the DesignJet 230 and 250C

The service configuration plot contains the following information:

DesignJet 230/250C Service Configuration Plot

Firmware Release: X.XX.XX

SPROC release: X.X

(Servo-Processor Code revision number.)

EEROM Contents

EEROM CONTENTS

(This is for the plotter design engineers to interpret.)

NOTE: All EEPROM Parameters are since last EEROM Reset.

Number of Power Cycles:

(Number of times plotter has been switched on.)

Number of Color Plots:

Number of Black Plots:

Number of Pens:

(Number of times each cartridge has been replaced. Cyan, Magenta, Yellow, Black.)

Factory Spittoon:

(The estimated level of ink in the spittoon. Incorrect if you have cleared the EEROM.)

Number of Bail Errors:

Number of System Errors:

Last System Error:

(To correctly interpret this information, refer to page 8-19.)

Last System Error Data:

(To correctly interpret this information, refer to page 8-19.)

Bench Run:

(Whether the bench run has been performed.)

Bench Run Maximum Y-Axis (Carriage-Axis) PWM:

(This should be less than 102. Typical value = 75.)

Bench Run Maximum X-Axis (Media-Axis) PWM:

(This should be less than 65. Typical value = 52.)

Encoder-Tests Maximum Y-Axis (Carriage-Axis) PWM:

(This should be less than 102. Typical value = 75.)

Encoder-Tests Maximum X-Axis (Media-Axis) PWM:

(This should be less than 65. Typical value = 52.)

Last Accuracy Calibration:

Factory Calibration Factor:

(This is the drive-roller correction factor, calculated during accuracy calibration. It should be approximately 1.

Less than 0.9 means the drive-roller radius is too small. Greater than 1.1 means the drive-roller radius is too big.)