230
250C
Media Type
Read Settings
Print Quality
Align Cartridges
Cancel
Replot
8Ć54 Troubleshooting
C4699Ć90000
Clearing the EEROM for the DesignJet 230 and 250C
If you clear the calibration parameters, you will then need to perform the plotter
calibrations. (Details
' chapter 7.) Clearing the EEROM also resets the factory
spittoon value to 0% used. Keep in mind that the value printed on the service
configuration plot may greatly underestimate the amount of ink in the spittoon.
C A U T I O N
Clearing Just the Benchrun and Calibration Parameters
1 Switch the plotteroff.
2 While holding both the
Read Settings
and
Media Type
keys down,
switch the plotteron.
3 Once the the LEDs begin to light up one by one, release the
Read Settings
and
Media Type
keys.
Clearing Just the UserĆDefined SetupParameters
1 Switch the plotteroff.
2 While holding both the
Align Cartridges
and
Print Quality
keys
down, switch the plotteron.
3 Once the the LEDs begin to light up one by one, release the
Align Cartridges
and
Print Quality
keys.
Clearing All Parameters
1 Switch the plotteroff.
2 While holding both the
Cancel
and
Replot
keys down,
switch the plotteron.
3 Once the the LEDs begin to light up one by one, release the
Cancel
and
Replot
keys.