Calibrations and Adjustments

C4699Ć90000

Before Performing the Accuracy Calibration

1 Under normal environmental conditions and on HP inkjet polyester D/A1Ćsize media, plot

a drawing that contains two X" marks nominally positioned 500 mm (19.69 in.) apart.

2 Measure the distance between the centers of the X" marks on the plot.

Accuracy calibration is needed if this distance is not 500 mm (19.69 in) 1 mm (0.04 in).
If the measured accuracy, media thickness, or environmental conditions vary greatly from

the factory standards, recalibrate the plotter by continuing with the following procedure.

Performing the Accuracy Calibration on the DesignJet 230 and 250C

1 Read w Before Performing the Accuracy Calibration above.
2 Place a sheet of HP inkjet polyester film over the top of the plotter for 10 minutes to let

the sheet stabilize to the environmental conditions.
Use a sheetof approximate size A1 or D.
You must use polyester film. Otherwise the optical sensor on the carriage will be

calibrated incorrectly, and the plotter will have problems loading some types of media.

3 In

service mode 2

, set the

Media Type

on the front panel

to

Film

.

4 Load the film, with the matte (dull) side down, in portrait

orientation into the plotter.

5 When the

Ready

LED lights up, holddown the

SHIFT

key andpress

Accuracy Calib. Print.

The

Ready

LED begins to flash and the plotter plots a

calibration plot. The plotter ejects the sheet, and the

Load Media

LED lights up.

6 Unloadthe sheet.
7 Cut the blank endoff the film by cutting along the long dashedline on the plot; the cut

must be very straight.

Cut along this line

Film

Media Type