8Ć36 Troubleshooting

C4699Ć90000

Align

Cartridges

+

Service Mode 1 (230/250C)

(Details

' page 7-3.)

Shift

Stopping most Tests

Service-Mode 2

(Details

' page 7-4.)

Print

Quality

+

Form

Feed

+

Service Mode 1 (330/350C)

(Details

' page 7-3.)

Viewing Test Output on an HP Palmtop PC

Some of the tests in service mode 1 send test information to the plotter's serial port. To view

the information on an HP Palmtop PC, perform the procedure below.

1 Turn the plotter and Palmtop off.
2 Use HP cable number F1015Ć80002 and adapter number 5181Ć6640 to connect the

Palmtop to the plotter's serial interface port.
Both cable and adaptor are included in the HP F1021B Connectivity Pack.

3 Turn the plotter on in service mode 1.
4 Turn the Palmtop on.
5 Open the

Data Comm

application on the Palmtop.

6 Press

MENU

.

7 Move to the

Connect

menu and press

ENTER

.

8 Ensure that

Settings

are the same for both plotter and Palmtop.

9 Again move to the

Connect

menu and press

ENTER.

10 With

Connect

highlighted in the

Connect

menu, press

ENTER.

11 Perform the service tests on the plotter.
To stop communication between the plotter and the Palmtop, highlight

Hangup

in the

Connect

menu and press

ENTER

.