HP 250C User Manual
Page 151
Plain + Load Media + Error + Film:
Problems in the free movement of the
carriage.
The possible causes could be: D Something is causing excessive friction in the
YĆaxis (carriage axis). D The carriage touches the bail as it moves.
Steady 1234
Plain + Load Media + Error + Fast:
Error detected in mediaĆaxis servo feedback
loop.
The problem may be with the: D MediaĆmotor encoder cable D Media motor
D Electronics module.
Steady 1235
Plain + Error + Film + Ready:
Failure of Centronics READ.
Firmware error or faulty electronics module.
Steady 1346
Plain + Error + Fast + Roll:
Communication broken between the two
processors on the main PCA.
Replace the electronics module.
Steady 1359
Error + Ready + Roll:
Library Error.
Special firmware error. See Steady 1389.
Steady 369
Plain + Error +Film + Normal:
Electrical error
The possible causes could be: D Missing or badly seated cartridge. D One
end of the trailing cable is not connected or is badly connected, or the trailing
cable is faulty. D Faulty fan, or fan is disconnected. D Faulty carriage PCA.
D Faulty main PCA.
Steady 1348
Plain + Error + Film + Fast:
Not enough memory for the sensor data structure.
D Turn the plotter off, and then on again to see if the problem disappears.
D If the problem remains, consult recent service notes for a possible solution.
D If no service note deals with this error, report the problem to your HP
Response Center. Note conditions and actions before error occurred. Include
setup sheet and service configuration plot in report.
Steady 1345
8Ć17
Troubleshooting
C4699Ć90000