Table 2-17
Physical Environmental Specifications
Condition
Voltage
200–240 Vac
Airflow,
Nominal
Airflow,
Maximum
at 32
o
C
a,b
a. Derate maximum dry bulb temperature 1oC/300 m above 900 m.
b. The system deviates slightly from front to top and rear airflow protocol. Approximately 5 percent of
the system airflow is drawn in from the rear of the system. See Figure 2-2 on page 73 for more
details.
Weight
Overall System
Dimensions
(W X D X H)
Typical
Heat
Release
Description
Watts
CFM
m
3
/hr
CFM
m
3
/hr
lb
kg
in
mm
Minimum
Configuration
3423
2900
5.0
2900
5.0
926.3
420.3
30x48
x77.2
76.2x121.9
x195.6
Maximum
Configuration
9130
2900
5.0
2900
5.0
1241.2
563.2
30x48
x77.2
76.2x121.9
x195.6
Typical
Configuration
6968
2900
5.0
2900
5.0
1135.2
515.1
30x48
x77.2
76.2x121.9
x195.6
ASHRAE
Class
1
Minimum
Configuration
c
c. See Table 2-15 on page 69 and Table 2-16 on page 70 for additional details regarding minimum,
maximum, and typical configurations.
2 Cell, 4 DIMM, 2 I/O
Maximum
Configuration
8 Cell, 32 DIMM, 4 I/O
Typical
Configuration
6 Cell, 16 DIMM, 4 I/O