beautypg.com

Mp command: re, Re - reset entity, Access level—operator – HP A9834-9001B User Manual

Page 200: Scope—complex, Example

background image

Appendix B

Management Processor Commands

MP Command: RE

200

MP Command: RE

RE - Reset Entity

Access level—Operator

Scope—Complex

This command resets the specified entity. Care should be exercised when resetting entities because of the side
effects. Resetting an entity has the following side effects.

– Main backplane - The CLU asserts the backplane_reset signal on the backplane which results in the
following being reset:

* All XBCs, RCs, cells plugged into backplane, Dillons, CCs, all CPUs except PDHC, any attached RIOs, all
I/O adapters installed in the I/O backplanes associated with the above RIOs.

– Cell - The SINC asserts the mpon signal to Dillon which results in the following being reset:

* Dillon, CC, all CPUs except SINC, any attached RIO, all I/O adapters installed in the I/O backplane
associated with the above RIO

– I/O backplane - The CLU asserts the iobackplane_reset signal to the appropriate I/O backplane which
results in the following being reset:

* RIO and all I/O adapters installed in the I/O backplane

• Example:

MP:CM> re

This command resets a hardware device.

C - Cell

I - IO Chassis

M - Main Backplane

Select device: m

Enter cabinet number: 0

Do you want to reset the Main Backplane in Cabinet 0? (Y/[N]) y

-> The selected device(s) will be reset.

MP:CM>

• See also: PE