Table 2-16
Typical HP Integrity Superdome/sx2000 for Single-core CPU
Configurations
a
Cell
Memory
IO
Typical
Power
(Watts)
Cooling
(Btu/Hr)
Breaker
Power
(Watts)
b
8
32
4
9130
31181
11503
8
16
2
7260
24794
9147
8
8
4
7783
26580
9806
8
8
2
6823
23302
8596
8
4
4
7260
24794
9147
8
4
2
6300
21516
7938
6
16
4
6968
23797
8779
6
16
2
6008
20518
7570
6
8
4
6640
22677
8366
6
8
2
5680
19398
7156
6
4
4
6325
21601
7969
6
4
2
5365
18322
6759
4
16
4
5813
19852
7324
4
16
2
4853
16574
6114
4
8
4
4647
15870
5855
4
8
2
3687
12592
4645
4
4
4
5382
18380
6781
4
4
2
4422
15102
5571
2
16
2
3656
12486
4606
2
8
2
3534
12069
4453
2
4
2
3423
11690
4313
a. Values in Table 2-15 are based on 25 W load I/O cards, 1
GB DIMMs and four Intel
Itanium 2 single-core
processors with 9 MB cache per cell board.