Matrix Software, cont’d

MVX Plus 128 VGA Matrix Switchers • Matrix Software

5-8

PRELIMINAR

Y

Gateway IP address fi eld

The Gateway IP Address fi eld identifi es the address of the gateway to the mail
server to be used if the MVX Plus 128 switcher and the mail server are not on the
same subnet.

Valid IP addresses consist of four 1-, 2-, or 3-digit numeric octets separated by dots
(periods). Each fi eld can be numbered from 000 through 255. Leading zeroes, up to
3 digits total per fi eld, are optional. Values of 256 and above are invalid.

Edit this fi eld as follows:

1

.

Click in the Gateway IP Address fi eld. The graphic cursor becomes a text
cursor.

2

.

Edit the address as desired.

3

.

Press the Tab key on the keyboard or click in another fi eld to exit the Gateway
IP Address fi eld.

4

. Click

the

Take button to make the address change take affect.

Subnet Mask fi eld

The Subnet Mask fi eld is used to determine whether the MVX Plus 128 switcher
is on the same subnet as the controlling PC or the mail server when you are
subnetting. For more information, see Subnetting — A Primer, in Appendix A,
Ethernet Connection.

Edit this fi eld as follows:

1

.

Click in the Subnet Mask fi eld. The graphic cursor becomes a text cursor.

2

.

Edit the mask as desired.

3

.

Press the Tab key on the keyboard or click in another fi eld to exit the Subnet
Mask fi eld.

4

. Click

the

Take button to make the mask take affect.

Hardware Address fi eld

The hardware address is hardcoded in the MVX Plus 128 switcher and cannot be
changed.

Use DHCP checkbox

The Use DHCP checkbox directs the MVX Plus 128 switcher to ignore any entered
IP addresses and to obtain its IP address from a Dynamic Host Confi guration
Protocol (DHCP) server (if the network is DHCP capable). Contact the local system
administrator.

Date fi eld

The Date fi eld displays the current date in the Greenwich
Mean Time zone. If necessary, adjust the date as follows:

1

.

Click in the Date fi eld. A set date fi eld appears with the date in the format
(M)M/(D)D/YYYY. Leading zeroes are not used. The graphic cursor
becomes a text cursor in the set date fi eld.

2

.

Edit the fi eld as desired to set the proper date. Leading zeroes are optional.

3

.

Press the Tab key on the keyboard or click in another fi eld to exit the set date
fi eld.