Page 73: Default ip addresses
4-3
MVX Plus 128 VGA Matrix Switchers • Programmer’s Guide
PRELIMINAR
Y
Ethernet Link
The rear panel Ethernet connector on the switcher can be connected to an Ethernet
LAN or WAN. This connection makes SIS control of the switcher possible using a
computer connected to the same LAN or WAN.
Ethernet connection
The Ethernet cable can be terminated as a straight-through cable or a crossover
cable and must be properly terminated for your application (fi gure 4-2).
• Crossover cable — Direct connection between the computer and the
MVX Plus 128 switcher.
• Patch (straight-through) cable — Connection of the MVX Plus 128 switcher
to an Ethernet LAN.
Clip Down
Side
1
1&2
3&6 4&5
7&8
2 3 4 5 6 7 8
1
Pins
2 3 4 5 6 7 8
RJ-45
connector
Patch (straight) cable
Twisted
Pairs
Side 1
Side 2
Pin
Wire color
Pin
Wire color
1
White-orange
1
White-orange
2
Orange
2
Orange
3
White-green
3
White-green
4
Blue
4
Blue
5
White-blue
5
White-blue
6
Green
6
Green
7
White-brown
7
White-brown
8
Brown
8
Brown
Crossover cable
Side 1
Side 2
Pin
Wire color
Pin
Wire color
1
White-orange
1
White-green
2
Orange
2
Green
3
White-green
3
White-orange
4
Blue
4
Blue
5
White-blue
5
White-blue
6
Green
6
Orange
7
White-brown
7
White-brown
8
Brown
8
Brown
Figure 4-2 — RJ-45 Ethernet connector pin assignments
Default IP addresses
To access the MVX Plus 128 switcher via the Ethernet port, you need the Extron
IP address, and may need the subnet mask and the gateway address. If the IP
address has been changed to an address comprised of words and characters, you
can determine the actual numeric IP address using the ping (ICMP) utility (see
appendix A, Ethernet Connection, for more details). If the addresses have not been
changed, the factory-specifi ed defaults are:
• IP address
192.168.254.254
• Subnet mask
255.255.0.0
• Gateway address 0.0.0.0