SIS

Programming and Control, cont’d

MVX Plus 128 VGA Matrix Switchers • Programmer’s Guide

4-6

PRELIMINAR

Y

Command/Response Table for SIS Commands

Symbol defi nitions

]

= CR/LF (carriage return/line feed) (hex 0D 0A)

}

= Carriage return (no line feed, hex 0D)

(use the pipe character,

|

, instead for Web browser commands)

= Space character

|

= Pipe (vertical bar) character

E

= Escape key (hex 1B)

(use W instead of Esc for Web browsers)

X!

= Input number

01 – 12

X@

= Input number (for tie)

00 – 12 (00 = untied)

X#

= Output number

01 – 08

X$

= Numeric dB value

–18 to +24 (45 steps of gain or attenuation)

X%

= Audio gain

0 – 24 (1 dB/step)

X^

= Audio attenuation

1 – 18 (1 dB/step)

X&

= Volume adjustment range

0 – 64 (1 dB/step except for 0-to-1, which is 34 dB)

(see the table on page 4-9)

X*

= Room # (for room presets)

10 max. (each can have up to 10 presets (

X1@

s) assigned)

N A Room is a subset of operator-selected outputs that relate to each other. The MVX Plus 128 switcher supports up to 10 rooms, each of

which can consist of from 1 to 16 outputs.

X(

= Mute, executive mode, power supply

(0 = off/not OK, 1 = on/OK)

X1)

= Group # (for I/O grouping)

1 through 4 groups (0 = no group)

X1!

= Global preset #

32 maximum (0 = current confi guration)

X1@

= Room preset #

10 maximum (0 = current confi guration for room)

N A Room preset is a stored confi guration with all of the outputs assigned to a single room. When a room preset is retrieved from memory,

it becomes the current confi guration.

X1#

= RGB delay interval

Delay in ½ second increments (10 maximum)

X1$

= Video/audio mute:

0 = no mutes

1 = video mute

2 = audio mute

3 = video and audio mute

X1%

= Sync frequency

xxx.xx (frequency in Hz (V) or kHz (H))

X1(

= Firmware version number to second decimal place (x.xx)

X2)

= Verbose fi rmware version-description-upload date/time. See page 4-15.

X2#

= Name

12 characters maximum for global and room preset names

11 characters maximum for room names

Upper- and lower-case alphanumeric characters and

_ : = / and spaces are valid.

N The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

X2$

= Voltage

Positive or negative voltage and magnitude

X2%

= Temperature

Degrees Fahrenheit